Liquid based Pap test
Liquid based Pap test
Liquid based Pap test, Maturation Index
Liquid based Pap test, Maturation Index
| Specimen Type | Methodology | Requirements | Containers | Collection Protocols |
|---|---|---|---|---|
| Peripheral Blood | Flow Immunophenotype | 2–5 ml of blood, 1 freshly prepared smear (preferred) | Green Top (Sodium Heparin), Purple Top (EDTA), Yellow Top (ACD) | Label the tube with the patient’s name, the date and time that the specimen was drawn. Keep the sample at room temperature and use Flow Cytometry shipping package for transport. |
| Bone Marrow Aspirate | Flow Immunophenotype | 1–3 ml of bone marrow, 1 freshly prepared smear (preferred) | Green Top (Sodium Heparin) (Preferred), or Purple Top (EDTA), or Yellow Top (ACD) | Label the tube with the patient’s name, the date and time that the specimen was drawn. Do not draw more than 2 mls/tube. Keep the sample at room temperature and use Flow Cytometry shipping package for transport. |
| Bone Marrow Biopsy Core | Flow Immunophenotype | 1–2 cm bone core | RPMI 1640 or other tissue culture media, Sterile saline solution | Immerse the biopsy into the RPMI 1640. Keep the sample at room temperature or refrigerated and use Flow Cytometry shipping package for transport. |
| Fresh Tissue Biopsy | Flow Immunophenotype | Approximately 0.5 cm x 0.5 cm x 0.5 cm, H&E slide, if available | Tissue culture media (RPMI 1640 / Hank’s solution), Sterile saline solution | Cut tissue specimen in thin slices (no more than 1.0 mm thick). Immerse the tissue into the RPMI 1640. Keep the sample at room temperature or refrigerated and use Flow Cytometry shipping package for transport. |
| Fine Needle Aspirate | Flow Immunophenotype | As many needle passes as possible | Sterile tissue culture media (RPMI 1640) | Irrigate the collected aspirate into RPMI 1640. Keep the sample at room temperature or refrigerated and use Flow Cytometry shipping package for transport. |
| Body Fluids | Flow Immunophenotype | Provide approx. 50 ml or as much as possible (CSF at least 2.0 ml) | Sterile container | Keep the sample at room temperature or refrigerated and use Flow Cytometry shipping package for transport. |
Caution:
1. RPMI is expired when it turns yellow, cloudy or beyond expiration date. Use only pink color RPMI 1640.
2. Be sure cold pack is not in direct contact with specimen during transport.
3. After the bone marrow or peripheral blood is drawn, please prepare 2 fresh smears and provide CBC results along with the samples.
For local pick ups, please call Medical Laboratory Services at 951-834-9020 to arrange a pickup schedule by our couriers.
For FedEx shipping, place the Flow Cytometry shipping package in the FedEx shipping plastic bag and ship it overnight. Make sure to check the appropriate box for Saturday delivery. Call Medical Laboratory Services on Friday concerning any Saturday delivery.
For more shipping packages or any questions regarding sample shipping, please contact MLS at 951-834-9020.
SurePath Specimens: Rovers Cervex-Brush collection device is recommended in all cases. For patients without a cervix, a vaginal cuff specimen is recommended. Insert tip of collection device into endocervical canal, rotate device five times in a clockwise direction while applying gentle pressure to the handle, remove collection device from endocervical canal. Using thumb and forefinger remove the detachable head from the handle and drop detachable head into fixative vial. Securely re-apply cap to fixative vial. Label the fixative vial with two unique patient identifiers.
ThinPrep Specimens: Papette collection device is recommended in all cases. For patients without a cervix, a vaginal cuff specimen is recommended. Insert tip of collection device into endocervical canal, rotate device five times in either direction while applying gentle pressure to the handle, remove collection device from endocervical canal. Rinse the Papette brush into the collection vial solution by pushing the brush into the bottom of the vial 10 times forcing the bristles apart. Swirl the brush vigorously to further release material. Remove collection device from vial and discard the collection device. Securely re-apply cap to fixative vial. Label the fixative vial with two unique patient identifiers.
SurePath Specimens: Rovers Cervex-Brush collection device is recommended in all cases. For patients without a cervix, a vaginal cuff specimen is recommended. Insert tip of collection device into endocervical canal, rotate device five times in a clockwise direction while applying gentle pressure to the handle, remove collection device from endocervical canal. Using thumb and forefinger remove the detachable head from the handle and drop detachable head into fixative vial. Securely re-apply cap to fixative vial. Label the fixative vial with two unique patient identifiers.
ThinPrep Specimens: Papette collection device is recommended in all cases. For patients without a cervix, a vaginal cuff specimen is recommended. Insert tip of collection device into endocervical canal, rotate device five times in either direction while applying gentle pressure to the handle, remove collection device from endocervical canal. Rinse the Papette brush into the collection vial solution by pushing the brush into the bottom of the vial 10 times forcing the bristles apart. Swirl the brush vigorously to further release material. Remove collection device from vial and discard the collection device. Securely re-apply cap to fixative vial. Label the fixative vial with two unique patient identifiers.
SurePath Specimens: Rovers Cervex-Brush collection device is recommended in all cases. For patients without a cervix, a vaginal cuff specimen is recommended. Insert tip of collection device into endocervical canal, rotate device five times in a clockwise direction while applying gentle pressure to the handle, remove collection device from endocervical canal. Using thumb and forefinger remove the detachable head from the handle and drop detachable head into fixative vial. Securely re-apply cap to fixative vial. Label the fixative vial with two unique patient identifiers.
ThinPrep Specimens: Papette collection device is recommended in all cases. For patients without a cervix, a vaginal cuff specimen is recommended. Insert tip of collection device into endocervical canal, rotate device five times in either direction while applying gentle pressure to the handle, remove collection device from endocervical canal. Rinse the Papette brush into the collection vial solution by pushing the brush into the bottom of the vial 10 times forcing the bristles apart. Swirl the brush vigorously to further release material. Remove collection device from vial and discard the collection device. Securely re-apply cap to fixative vial. Label the fixative vial with two unique patient identifiers.